Based on signal processing and extraction, this article proposes a model for the automatic and objective counting of consecutive matching striae (CMS).
The consecutive matching striae (CMS) numeric criteria for firearm and toolmark identifications have been widely accepted by forensic examiners, although there have been questions concerning its observer subjectivity and limited statistical support. In the current project, the position and shape information of the striae on the bullet land was represented by a feature profile, which was used for determining the CMS number automatically. Rapid counting of CMS number provides a basis for ballistics correlations with large databases and further statistical and probability analysis. Experimental results in this report using bullets fired from 10 consecutively manufactured barrels support this developed model. (Publisher Abstract)
Downloads
Similar Publications
- Recovery and Detection of Ignitable Liquid Residues from the Substrates by Solid Phase Microextraction – Direct Analysis in Real Time Mass Spectrometry
- Evaluation of Cannabis Product Mislabeling: The Development of a Unified Cannabinoid LC-MS/MS Method to Analyze E-liquids and Edible Products
- Just Science Podcast: Just Rapidly Identifying Drugs Involved in Suspected Overdoses