The authors report on the researchers’ method validations on different instruments, to compare detection (LOD) and quantitation (LOQ) limits, repeatability of results, and reliability of concentration predictions; they also provide recommendations to help managers and practitioners with strategies for incorporating organic gunshot residue in their workflow.
This study assesses the capabilities and limitations of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC–MS) for the trace detection of organic gunshot residue (OGSR), at a time when forensic scientific organizations in the U.S are developing standards to facilitate their adoption. Here, recommendations are provided to aid managers and practitioners with strategies for incorporating OGSR in their workflow. Limits of detection (LODs), limits of quantitation (LOQs), and measurement variability are reported for top eight analytes of interest: nitroglycerin, 2,4-dinitrotoluene, akardite II, methyl centralite, ethyl centralite, diphenylamine, 2-nitrodiphenylamine, and 4-nitrodiphenylamine. Both techniques detected the targeted analytes with LODs as low as 0.3 ppb for LC-MS/MS and 40 ppb for GC–MS. The methods’ performance rates were evaluated using 50 shooter sets, including four different ammunition types. Background specimens were collected from individuals who had not handled a gun in the last 24 hours. The solvent extracts were split in half for a direct comparison of the methods on the same specimens. For the ammunition used here, enhanced sensitivity was observed for the triple quadrupole configuration (LC-MS/MS), with accuracies as high as 80 percent. However, under the extraction and EI-quadrupole instrumental configuration used in this study, GC–MS could not detect enough characteristic compounds to identify OGSR, especially in lower calibers. As a result, the GC–MS analysis displayed accuracies only as high as 35 percent, raising a flag that GC–MS alone is not recommended for OGSR detection unless combined with LC-MS/MS, or used with alternative pre-concentration methods or high-resolution configurations. (Published Abstract Provided)
Downloads
Similar Publications
- Determining Fracture Timing from Microscopic Characteristics of Cortical Bone
- Grooming Traffickers: Investigating the Techniques and Mechanisms for Seducing and Coercing New Traffickers
- Improving Outcomes for Child and Youth Victims of Commercial Sexual Exploitation: An Evaluability Assessment of the Love 146 Survivor Care Programs