We describe a liquid chromatography–tandem quadrupole mass spectrometry method for the quantification of nine analogs and/or metabolites of drugs in this series: isotonitazene, metonitazene, protonitazene, etonitazene, clonitazene, flunitazene, N-desethyl isotonitazene, 5-amino isotonitazene and 4ʹ-hydroxy nitazene in human whole blood, urine, and tissue.
In the current project, chromatographic separation was achieved using a C-18 analytical column. Multiple reaction monitoring mode was used for detection. The calibration range for the analytes was 0.5–50 ng/mL (except for 5-amino isotonitazene, which was 1.0–50 ng/mL). The limit of detection was 0.1 ng/mL, and the limit of quantitation was 0.5 ng/mL. The method had no carryover or interferences. Ionization enhancement was observed but did not affect quantitation. All analytes passed the method validation assessment. Authentic human samples suspected of containing NSOs were obtained from a medical examiner and coroner offices, as well as partnering forensic toxicology laboratories. Isotonitazene was confirmed in 92 blood samples, and its metabolites were confirmed across various matrices. Metonitazene (n = 35), flunitazene (n = 5), protonitazene (n = 3), etodesnitazene (n = 2) and butonitazene (n = 1) were also detected in cases. These newly emerging 2-benzylbenzimidazole analogs were commonly found in combination with NPS benzodiazepines and opioids (e.g., flualprazolam, fentanyl). Nitazene analogs are potent esoteric drugs that may not be identified during routine toxicological screening, and specialized assays based on sensitive instrumentation are needed to accurately characterize these NSOs. (Publisher Abstract)
Downloads
Similar Publications
- Analyzing and interpreting deoxyribonucleic acid from multiple donors using a forensically relevant single-cell strategy
- Wastewater Surveillance for Xylazine in Kentucky
- Superhydrophobic Surface Modification of Polymer Microneedles Enables Fabrication of Multimodal Surface-Enhanced Raman Spectroscopy and Mass Spectrometry Substrates for Synthetic Drug Detection in Blood Plasma