U.S. flag

An official website of the United States government, Department of Justice.

Validation of CFD fire model pressure predictions for modern residential style structures

NCJ Number
304289
Date Published
December 2021
Annotation

This article reports on controlled gas-burner experiments that were conducted in single- and two-story residential style structures instrumented with pressure transducers, thermocouples, and bi-directional probes throughout the structures.

Abstract

Exterior doors and window openings were vented in a controlled sequence to investigate the effect of the resulting flow paths on fire-induced flow dynamics and thermal conditions in the structures. The data collected in these experiments provides validation cases for the fire modeling community which currently lacks full-scale data from experiments in realistic residential style structures. The Fire Dynamics Simulator was used to model each scenario in a validation exercise that also investigated the sensitivity of the pressure predictions to the model parameters. The model could predict the qualitative changes in pressure measurements due to ventilation events as well as the apparent elevation of the neutral plane. Peak pressures were predicted to within 6 percent on average and quasi-steady static pressures were predicted to within 24 percent on average. The mean instantaneous error between the experimental pressures and those predicted with the “Localized Leakage” method was approximately 53 percent compared to 67 percent with the “Pressure Zone Leakage” method prior to the first ventilation event. (publisher abstract modified)

Date Published: December 1, 2021