NCJ Number
235779
Journal
Journal of Forensic Sciences Volume: 56 Issue: 4 Dated: July 2011 Pages: 835-845
Date Published
July 2011
Length
11 pages
Annotation
This article reviews the AmpFlSTR Identifiler Direct PCR Amplification Kit.
Abstract
The AmpFlSTR Identifiler Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single-source blood and buccal samples on FTA card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay's sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA cards, and the assay's specificity was verified by establishing minimal cross-reactivity with nonhuman DNA. No affect on the age of the sample stored on the FTA substrata was observed, and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler Direct Kit for forensic standards and database samples genotyping. (Published Abstract)