U.S. flag

An official website of the United States government, Department of Justice.

NCJRS Virtual Library

The Virtual Library houses over 235,000 criminal justice resources, including all known OJP works.
Click here to search the NCJRS Virtual Library

A Systematic Study of Liquid Chromatography in Search of the Best Separation of Cannabinoids for Potency Testing of Hemp-Based Products

NCJ Number
310229
Journal
Molecules Volume: 30 Issue: 4 Dated: Feb 2025 Pages: 758
Author(s)
Ayowole Owolabi; Olalekan Ogunsola; Emma Joens; Medline Kotler; Liguo Song
Date Published
February 2025
Annotation

This paper describes a systematic examination of liquid chromatography in search of the best separation of cannabinoids for potency testing of hemp-based products.

Abstract

In this study, researchers systematically evaluated liquid chromatography seeking the best separation of eighteen cannabinoids, the maximum number of cannabinoids quantified so far, for potency testing of hemp-based products using liquid chromatography diode array detector (LC-DAD). The investigation utilized four column types, all sharing the same dimension (150 mm × 2.1 mm) and core–shell particle size (2.7 µm), but different stationary phases: dimethyl-octadecyl (Poroshell 120 EC-C18), diisobutyl-octadecyl (Raptor ARC-18), reverse phase (RP)-carbamate (Cortecs Shield RP-18), and RP-amide (Ascentis Express RP-Amide). The resolution of adjacent cannabinoids was kept close to 1.5 or higher, while the separation time was kept as short as possible. The fastest separation was achieved within 15.0 min using two sequential Raptor ARC-18 columns, with a mobile phase consisting of 75.0% acetonitrile and 25.0% aqueous solution of 0.03% formic acid and 0.5 mM ammonium formate at pH 2.97, at a flow rate of 0.5 mL/min. A slightly improved resolution of the eighteen cannabinoids was obtained within 18.5 min using two sequential Poroshell 120 EC-C18 columns under similar conditions, except for a mobile phase containing 77.5% acetonitrile and a reduced flow rate of 0.45 mL/min due to backpressure higher than 600 bars. Furthermore, a rapid 7.0 min separation was achieved for potency testing of hemp-based products by liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) using a Cortecs Shield RP-18 column, with a mobile phase consisting of 70.0% acetonitrile and 30.0% aqueous solution of 0.01% formic acid and 1 mM ammonium formate at pH 3.38 at a flow rate of 0.5 mL/min. (Published Abstract Provided)