U.S. flag

An official website of the United States government, Department of Justice.

NCJRS Virtual Library

The Virtual Library houses over 235,000 criminal justice resources, including all known OJP works.
Click here to search the NCJRS Virtual Library

Using the Scanning Electron Microscope to Identify the Cause of Fibre Damage Part II: An Exploratory Study

NCJ Number
157555
Journal
Canadian Society of Forensic Science Journal Volume: 28 Issue: 3 Dated: (September 1995) Pages: 189-200
Author(s)
W Pelton; P Ukpabi
Date Published
1995
Length
12 pages
Annotation
A pilot study was conducted to determine the capability of the scanning electron microscope (SEM) technique to distinguish cuts from tears or to identify the particular mechanism used to damage a fabric by simply looking at fiber end appearance.
Abstract
A compact, plain woven structure of untextured multifilament nylon was selected as the test fabric. Damaged specimens were produced by a sharp carving knife, a sharp pair of dressmaker's shears, and an Elmendorf tear tester. Fourteen panelists received written instructions on how to assess fiber end damage based on comparisons with theoretical models and SEM micrographs of knife cut, scissor cut, and impact tear and ductile fracture fiber end appearances. Results showed that the recognition probability of correctly identifying the cause of damage was low and that fiber ends created by different damage mechanisms showed overlapping characteristics. Further research on fiber damage is recommended, and the authors suggest scientists exercise caution in using the SEM technique to identify the cause of fabric damage in criminal investigations. 11 references, 5 tables, and 4 figures